A flaw in ICMP packets in the Linux kernel may allow an attacker to quickly scan open UDP ports. This flaw allows an off-path remote attacker to effectively bypass source port UDP randomization. Software that relies on UDP source port randomization are indirectly affected as well on the Linux Based Products (RUGGEDCOM RM1224: All versions between v5.0 and v6.4, SCALANCE M-800: All versions between v5.0 and v6.4, SCALANCE S615: All versions between v5.0 and v6.4, SCALANCE SC-600: All versions prior to v2.1.3, SCALANCE W1750D: v8.3.0.1, v8.6.0, and v8.7.0, SIMATIC Cloud Connect 7: All versions, SIMATIC MV500 Family: All versions, SIMATIC NET CP 1243-1 (incl. SIPLUS variants): Versions 3.1.39 and later, SIMATIC NET CP 1243-7 LTE EU: Version

CWE

Идентификатор Описание
CWE-330 CWE-330: Use of Insufficiently Random Values

БДУ ФСТЭК

Идентификатор Описание
BDU:2020-05539 Уязвимость ядра операционных систем Linux, позволяющая нарушителю получить несанкционированный доступ к защищаемой информации

Доп. Информация

Product Status

Siemens Lunux Based Products
Product: Siemens Lunux Based Products
Vendor: n/a
Default status: Не определен
Версии:
Затронутые версии Статус
Наблюдалось в версии RUGGEDCOM RM1224: All versions between v5.0 and v6.4, SCALANCE M-800: All versions between v5.0 and v6.4, SCALANCE S615: All versions between v5.0 and v6.4, SCALANCE SC-600: All versions prior to v2.1.3, SCALANCE W1750D: v8.3.0.1, v8.6.0, and v8.7.0, SIMATIC Cloud Connect 7: All versions, SIMATIC MV500 Family: All versions, SIMATIC NET CP 1243-1 (incl. SIPLUS variants): Versions 3.1.39 and later, SIMATIC NET CP 1243-7 LTE EU: Versions 3.1.39 and later, SIMATIC NET CP 1243-7 LTE US: Versions 3.1.39 and later, SIMATIC NET CP 1243-7: Versions 3.1.39 and later, SIMATIC NET CP 1243-8 IRC: Versions 3.1.39 and later, SIMATIC NET CP 1542SP-1 IRC (incl. SIPLUS variants): Versions 2.0 and later, SIMATIC NET CP 1542SP-1: Versions 2.0 and later, SIMATIC NET CP 1543-1 (incl. SIPLUS variants): Versions 2.2 and later, SIMATIC NET CP 1543SP-1 (incl SIPLUS variants): Versions 2.0 and later, SIMATIC NET CP 1545-1: All versions, SINEMA Remote Connect Server: All versions prior to v3.0 SP1, TIM 1531 IRC (incl. SI ...[truncated*] affected
 

Ссылки

CVE Program Container

Обновлено: 04.08.2024
SSVC and KEV, plus CVSS and CWE if not provided by the CNA.

Ссылки

Мы используем cookie-файлы, чтобы получить статистику, которая помогает нам улучшить сервис для вас с целью персонализации сервисов и предложений. Вы может прочитать подробнее о cookie-файлах или изменить настройки браузера. Продолжая пользоваться сайтом, вы даёте согласие на использование ваших cookie-файлов и соглашаетесь с Политикой обработки персональных данных.